There’s a setting on your boiler you’ve probably never touched.

Most people haven’t. It was set when the boiler went in, usually far higher than it needs to be. And it’s been quietly adding to your gas bill every winter since.

Fixing it takes five minutes. It costs nothing. And most people never notice the difference, except on their bill.

So what is flow temperature?

Your boiler heats water and sends it round to your radiators.

The flow temperature is how hot that water is when it leaves the boiler.

It’s not your thermostat. The thermostat decides how warm the room gets. This decides how hot the radiators run while they get it there.

On a combi boiler, it has nothing to do with your taps or shower either. Your hot water stays exactly the same.

Here’s the thing: lots of combi boilers are sitting at 70 to 80°C. Most homes don’t need anything like that.

Why turning it down saves you money

Modern boilers have a clever trick. They can grab back heat from their own exhaust that would otherwise go straight out the pipe on your wall.

But they can only do it properly when they’re not running too hot.

At 80°C, that trick barely kicks in. You’re paying for heat that goes up the flue.

Drop it to around 60°C and the boiler spends far more of its time working the efficient way. Same warm house. Less gas.

How much less? Research for the charity Nesta found that going from 80°C to 60°C cut gas use by about 9%. Their more recent estimate is around £65 a year for a typical home.

Not life-changing. But for five minutes and zero cost, it’s one of the easiest wins there is.

Before you touch anything, check which boiler you have

This is the one bit that really matters, so give it a minute.

Not sure which you’ve got? The make and model are usually on the front or underneath. A quick search will tell you.

How to do it

  1. Find the radiator symbol. Most combis have two dials or two sets of buttons. The radiator one is your heating. Leave the tap one alone.
  2. Check where it’s set. No display? If it’s a dial marked 1 to 6, the middle is roughly 60°C. Your manual will say exactly.
  3. Turn it down to 60°C. Or 65°C if you have a hot water tank.
  4. Don’t touch your thermostat. Keep it where you like it.
  5. Give it a few days. Let the house settle before you judge.

Lost the manual? Search your boiler’s make and model plus “manual”. Nesta’s free Money Saving Boiler Challenge also walks you through it for most popular boilers.

Got a heat pump instead? Same idea, very different numbers. Here’s our heat pump flow temperature guide.

What it’ll feel like

Your radiators will feel warm, not scorching. That’s normal. That’s the point.

The house might take a little longer to heat up. In Nesta’s tests it was about 17 minutes longer, and only around half a degree cooler on average. If your heating’s on a timer, just bring it forward by 15 to 20 minutes.

Still cold on the really chilly days? Nudge it up a few degrees at a time, to 63°C or 65°C. You’re still saving compared with 80°C. Some homes with small radiators or not much insulation just need a bit more.

Feeling fine? Try going a little lower in spring and autumn. Plenty of boilers run happily at 55°C or even 50°C when it’s milder.

The short version

Find the radiator setting on your boiler. Turn it down to 60°C, or 65°C if you’ve got a hot water tank. Give it a few days.

That’s it.

If this helped, pass it on to someone who’s dreading their next gas bill.

Got a question about your boiler or your bills? Ask us for free and we’ll give you a straight answer.

Leave a Reply

Your email address will not be published. Required fields are marked *